LED Street Light for Roadway, Campus and Outdoor Area Projects
Besenled supports B2B street-lighting projects where buyers need to confirm pole height, road width, optical distribution, control method, outdoor durability, certification needs and RFQ information before selecting a fixture.
When should buyers choose LED street lights?
Choose street lights when the project needs continuous roadway, campus, parking-access or public outdoor illumination with controlled optics, pole mounting, outdoor protection, stable driver performance and quotation details based on site conditions.
- Roadway and campus outdoor lighting
- Specification and RFQ preparation
- Project-specific configuration
Application fit
Where LED street lights fit best
Street lights should be selected by site geometry and lighting outcome, not by wattage alone. The most useful RFQ starts with road width, pole height, pole distance, voltage, control requirement and target market.
Municipal roads
Public roadway or access-road lighting that needs optical control, safe visibility and project documentation.
Campus areas
Schools, parks, campuses, commercial complexes and public-facing outdoor circulation zones.
Industrial parks
Outdoor roads, logistics areas and perimeter access routes where durability and maintenance access matter.
Parking access roads
Outdoor approach roads and transition areas around commercial or mixed-use projects.
Selection framework
What buyers should confirm before choosing a street light
A street light quote becomes reliable only after the site geometry, electrical requirement, control plan and compliance market are clear.
| Buyer input | Why it matters |
|---|---|
| Road width | Helps decide optical distribution, wattage range and uniformity target. |
| Pole height | Affects lumen output, beam spread, glare control and mounting angle. |
| Pole distance | Controls dark zones, overlap and project-level spacing assumptions. |
| Mounting arm | Confirms installation diameter, tilt angle and mechanical compatibility. |
| Control method | Determines photocell, timer, dimming, motion sensor or smart-control options. |
| Destination market | Defines voltage, certification, document and compliance requirements. |
Structured product lineup
Street light models maintained as ACF Product records
This page now reflects the Street Light product records in the ACF Product system. The models below are organized for B2B specification review: power range, optical fit, outdoor protection, control readiness and RFQ requirements should be confirmed against the selected SKU before publishing final product detail pages.


LED street light
BS-SLA685 LED Street Light
BS-SLA685 is suitable when the project needs 30W-240W street lighting, IP66 outdoor protection, T2-M/T3-M distribution, photocell/timer/DALI options and tool-free maintenance.
- Power
- 30W-240W
- Efficacy
- 140LM/W (±5%)
- Protection
- IP66
- Optics
- T2-M / T3-M
Final photometric files and installation dimensions should be confirmed before specification. Some catalogue claims are marked for internal verification.
Request this model

LED street light
BS-SLA102 LED Street Light
BS-SLA102 fits projects needing 30W-200W LED street lights, 140lm/W efficacy, IP66/IK08 protection and 70*140° optical distribution.
- Power
- 30W-200W
- Efficacy
- 140LM/W (±5%)
- Protection
- IP66
- Optics
- 70*140°
Final photometric files and installation dimensions should be confirmed before specification.
Request this model

LED street light
BS-SLE630 LED Street Light
BS-SLE630 is relevant for 50W-300W street lighting where buyers need IP66/IK08 protection, SOSEN driver, 50,000-hour life and outdoor control options.
- Power
- 50W-300W
- Efficacy
- Confirm by final SKU
- Protection
- IP66
- Optics
- T2-M / T3-M
Final photometric files and installation dimensions should be confirmed before specification. Some catalogue claims are marked for internal verification.
Request this model

LED street light
BS-SLE630-B LED Street Light
BS-SLE630-B fits projects needing 50W-200W street lights with 3CCT and power adjustment, 70*140° distribution, IP66/IK08 protection and NEMA/ZHAGA accessory options.
- Power
- 50W-200W, adjustable steps listed: 50/40/30W, 100/80/60W, 150/120/90W, 200/160/120W
- Efficacy
- 140LM/W (±5%)
- Protection
- IP66
- Optics
- 70*140°
Final photometric files and installation dimensions should be confirmed before specification.
Request this model

LED street light
BS-SLE680 LED Street Light
BS-SLE680 is suitable for street lighting projects needing 50W-240W options, 140lm/W efficacy, IP66/IK08 protection and DALI/photocell/timer support.
- Power
- 50W-240W
- Efficacy
- 140LM/W (±5%)
- Protection
- IP66
- Optics
- T2-M / T3-M
Final photometric files and installation dimensions should be confirmed before specification.
Request this model

LED street light
BS-SLE620 LED Street Light
BS-SLE620 fits 50W-320W street lighting projects that need T2-M/T3-M optics, post-top or side-entry mounting, IP66 protection, corrosion-resistant optical cover and smart-ready accessory…
- Power
- 50W-320W
- Efficacy
- Confirm by final SKU
- Protection
- IP66
- Optics
- T2-M / T3-M
Final photometric files and installation dimensions should be confirmed before specification. Some catalogue claims are marked for internal verification.
Request this model

LED street light
LEMO LED Street Light
LEMO is a 50W-200W LED street light series with 140lm/W efficacy, 70*140° beam angle, IP66/IK08 protection and photocell/timer options.
- Power
- 50W-200W
- Efficacy
- 140LM/W (±5%)
- Protection
- IP66
- Optics
- 70*140°
Final photometric files and installation dimensions should be confirmed before specification.
Request this model

LED street light
EGO LED Street Light
EGO is a 50W-200W LED street light family using LUMILEDS LEDs, ZH driver, 140lm/W efficacy, IP66 protection and photocell/timer options.
- Power
- 50W-200W
- Efficacy
- 140LM/W (±5%)
- Protection
- IP66
- Optics
- 70*140°
Final photometric files and installation dimensions should be confirmed before specification.
Request this model

LED street light
ETO LED Street Light
ETO covers 30W-300W street lighting with 140lm/W efficacy, 70*140° beam angle, IP66/IK08 protection and photocell/timer options.
- Power
- 30W-300W
- Efficacy
- 140LM/W (±5%)
- Protection
- IP66
- Optics
- 70*140°
Final photometric files and installation dimensions should be confirmed before specification.
Request this model

LED street light
POMA LED Street Light
POMA is a 50W-200W street light family with LUMILEDS LEDs, ZH driver, 140lm/W efficacy, IP66/IK08 rating and photocell/timer options.
- Power
- 50W-200W
- Efficacy
- 140LM/W (±5%)
- Protection
- IP66
- Optics
- 70*140°
Final photometric files and installation dimensions should be confirmed before specification.
Request this modelSolar street light options
Solar models for projects without stable grid supply
Solar street lights require a separate check for solar panel size, battery capacity, charging time, autonomy days, installation environment and local sunlight conditions. Treat catalogue values as RFQ starting points, not final project guarantees.


Solar street light
POLA Solar Street Light
POLA is a solar street light family with 100W/200W listed power, 5-7 hour charging time, monocrystalline solar panel, IP66/IK08 protection and 5-year warranty.
- Power
- 100W-200W listed; page heading says 120W-200W
- Efficacy
- 140LM/W (±5%)
- Protection
- IP66
- Optics
- 70*140°
Final solar panel, battery and autonomy must be confirmed by selected SKU. Some catalogue claims are marked for internal verification.
Request this model

Solar street light
POHO Solar Street Light
POHO is a solar street light family with 100W-500W listed variants, 5-7 hour charging time, IP66/IK08 protection and 5-year warranty, but battery/runtime claims need project confirmation.
- Power
- 100W-500W listed; page heading says 50W-200W and table lists 100W/120W/300W/400W/500W, needs confirmation
- Efficacy
- 140LM/W (±5%)
- Protection
- IP66
- Optics
- 70*140°
Final solar panel, battery and autonomy must be confirmed by selected SKU. Some catalogue claims are marked for internal verification.
Request this modelTechnical specification checklist
Street light specifications to verify before quotation
The values below should be confirmed by model, destination market and project requirement. Do not treat estimated values as final project evidence.
| Wattage range | Confirm by road width, pole height and brightness target. |
|---|---|
| Luminous efficacy / lumen output | Confirm by selected LED, driver and thermal design. |
| CCT / CRI | Common outdoor CCT options should be confirmed by project standard and market preference. |
| Optical distribution | Confirm Type II, Type III, Type V or project-specific lens requirement when available. |
| Input voltage | Confirm regional voltage and driver compatibility before production. |
| IP / IK rating | Outdoor protection and impact resistance depend on final model and housing. |
| Surge protection | SPD requirement should be confirmed for outdoor grid and lightning-risk conditions. |
| Control options | Photocell, timer, dimming, sensor or smart-control options should be confirmed by project scope. |
| Warranty and documents | Warranty, datasheet, IES/LDT file and certificate availability should be confirmed by model. |
Choose the right outdoor fixture
Street light vs flood light vs bollard light
This comparison helps buyers avoid choosing a fixture only by wattage or appearance.
| Fixture type | Best for | Not ideal for |
|---|---|---|
| Street light | Roadway, campus road and pole-mounted outdoor circulation lighting. | Decorative facade washing or close-range accent lighting. |
| Flood light | Open yards, large-area coverage, signage and broad illumination. | Roadway projects that need controlled pole spacing and optical uniformity. |
| Bollard light | Low-level pathway, landscape and pedestrian guidance lighting. | Vehicle road main lighting or high-mount applications. |
| Linear / strip lighting | Architectural outlines, coves, facades and decorative linear effects. | Roadway main illumination. |
Evidence and compliance
Documents buyers should request for street-lighting projects
Certification and document availability depends on model and destination market. Confirm the exact requirement before using any claim as project evidence.
Datasheet
Model, power, lumen, voltage, CCT, CRI, IP/IK, size and installation data.
IES / LDT file
Photometric file for project simulation, distribution review and lighting layout discussion.
Certificates
CE, RoHS, CB, ENEC, UL, DLC or other documents only when applicable to the selected model.
Installation notes
Mounting arm, tilt, wiring, protection, maintenance and outdoor environment assumptions.
Project support process
How Besenled reviews a street-lighting request
- 1. Collect site inputs: road width, pole height, pole distance, voltage, environment and quantity.
- 2. Confirm lighting target: brightness expectation, uniformity requirement, glare concern and control method.
- 3. Match fixture configuration: wattage, optics, mounting, driver, protection and document needs.
- 4. Review evidence: datasheet, certificates, photometric file and installation assumptions.
- 5. Prepare RFQ: quotation basis, sample need, lead time, packaging and project-specific notes.
RFQ checklist
Send these details for a useful quotation
Road type and road width
Pole height and pole distance
Mounting arm size
Quantity and destination market
Input voltage
CCT and control method
IP / IK / certificate needs
Drawing or site photo if available
FAQ
Street light selection questions
How do I choose wattage for LED street lights?
Do not choose wattage alone. Confirm road width, pole height, pole distance, brightness target, optical distribution and control requirement first.
What pole height is suitable for street lights?
Pole height depends on road width, mounting arm, lighting target and selected optical distribution. Send the site dimensions before quotation.
What is the difference between street light and flood light?
Street lights are typically selected for pole-mounted roadway or campus-road illumination. Flood lights are better for broad area coverage where roadway-style optical spacing is not the main requirement.
Can street lights support photocell or smart control?
Selected configurations can support photocell, timer, dimming or smart-control options. Compatibility should be confirmed by driver, control protocol and project scope.
Can Besenled provide IES files or photometric data?
Photometric files should be confirmed by the selected model. Request IES or LDT data during RFQ if simulation or project review is required.
Next step
Build a street-lighting quote from real project inputs
Send road width, pole height, pole distance, voltage, quantity, control requirement and destination market. Besenled will review the configuration before confirming price, lead time and documents.